Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Inflamm Res ; 73(4): 531-539, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38498178

RESUMO

Metabolic remodeling is a key feature of macrophage activation and polarization. Recent studies have demonstrated the role of tricarboxylic acid (TCA) cycle metabolites in the innate immune system. In the current review, we summarize recent advances in the metabolic reprogramming of the TCA cycle during macrophage activation and polarization and address the effects of these metabolites in modulating macrophage function. Deciphering the crosstalk between the TCA cycle and the immune response might provide novel potential targets for the intervention of immune reactions and favor the development of new strategies for the treatment of infection, inflammation, and cancer.


Assuntos
Ciclo do Ácido Cítrico , Macrófagos , Ciclo do Ácido Cítrico/fisiologia , Macrófagos/metabolismo
2.
Sci Rep ; 14(1): 5095, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429374

RESUMO

The clinical application of conventional doxorubicin (CDOX) was constrained by its side effects. Liposomal doxorubicin was developed to mitigate these limitations, showing improved toxicity profiles. However, the adverse events associated with liposomal doxorubicin and CDOX have not yet been comprehensively evaluated in clinical settings. The FAERS data from January 2004 to December 2022 were collected to analyze the adverse events of liposomal doxorubicin and CDOX. Disproportionate analysis and Bayesian analysis were employed to quantify this association. Our analysis incorporated 68,803 adverse event reports related to Doxil/Caelyx, Myocet and CDOX. The relative odds ratios (RORs, 95%CI) for febrile neutropenia associated with CDOX, Doxil/Caelyx, and Myocet were 42.45 (41.44; 43.48), 17.53 (16.02; 19.20), and 34.68 (26.63; 45.15) respectively. For cardiotoxicity, they were 38.87(36.41;41.49), 17.96 (14.10; 22.86), and 37.36 (19.34; 72.17). For Palmar-Plantar Erythrodysesthesia (PPE), the RORs were 6.16 (5.69; 6.68), 36.13 (32.60; 40.06), and 19.69 (11.59; 33.44). Regarding onset time, significant differences adverse events including neutropenia, PPE, pneumonia and malignant neoplasm progression. This study indicates that clinical monitoring for symptoms of cardiotoxicity of CDOX and Myocet, and PPE and interstitial lung disease of Doxil should be performed. Additionally, the onset time of febrile neutropenia, malignant neoplasm progression, and pneumonia associated with Doxil and Myocet merits particular attention. Continuous surveillance, risk evaluations, and additional comparative studies between liposomal doxorubicin and CDOX were recommended.


Assuntos
Doxorrubicina/análogos & derivados , Neoplasias , Neutropenia , Pneumonia , Humanos , Cardiotoxicidade/tratamento farmacológico , Teorema de Bayes , Doxorrubicina/efeitos adversos , Lipossomos , Neoplasias/tratamento farmacológico , Neutropenia/induzido quimicamente , Pneumonia/tratamento farmacológico , Polietilenoglicóis
3.
Int J Anal Chem ; 2019: 7131907, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31320903

RESUMO

A direct and highly specific chemiluminescent enzyme-linked immunosorbent assay (CL-ELISA) method for monitoring chloramphenicol (CAP) in cosmetics has been developed. The anti-chloramphenicol antibody (mAb) adopted in this work for direct immunoassay could bind to CAP specifically, with negligible cross-reactivity (CR) (less than 0.01%) with most CAP analogues, including structurally related thiamphenicol (TAP) and florfenicol (FF). The limit of detection (LOD), measured by IC10, was 0.0021 ng mL-1. The detection range (IC20-IC80) was ranged from 0.00979 to 0.12026 ng mL-1. In spiked cosmetics samples, mean recoveries ranged from 82.7% to 99.6%, with intraday and interday variation less than 9.8 and 8.2%, respectively. Moreover, with the help of HRP-labeled anti-CAP mAb, the method could be processed in fast direct immunoreaction mode. This CL-ELISA method could be applied for specific, rapid, semiquantitative, and quantitative detection of CAP in cosmetics, facilitating the precise quality control of CAP contamination.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...